ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Right Side|Page 2641 > < Right Side|Page 2639
Page 2
background image

4. Remove the EGR valve to exhaust manifold tube.

-

Disconnect the upper and lower EGR valve to exhaust manifold tube fittings.

-

Disconnect the two DPFE hoses. 

5. Lift the fuel charging wiring off of the valve cover studs.

NOTE: 

-

The intake manifold is removed for clarity.

-

The bolts are part of the valve cover and should not be removed.

6. Remove the LH valve cover.

-

Fully loosen the bolts and remove the valve cover.

-

Inspect the valve cover gasket  and clean the mating surface of the cylinder head.

INSTALLATION

NOTE: If not secured within 4 minutes, the sealant must be removed and the sealing area cleaned with Metal Surface Cleaner F4AZ-19A536-A or
equivalent meeting Ford specification WSE-MSB392-RA. Allow to dry until there is no sign of wetness, or 4 minutes, whichever is longer. Failure
to follow this procedure can cause future oil leakage.

1. Apply a bead of silicone in two places where the engine front cover  meets the cylinder head.

-

Use Silicone Gasket and Sealer F6AZ-19562-AA or equivalent meeting Ford specification WSE-M4G323-A6.

Right Side|Page 2641 > < Right Side|Page 2639