ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|Description and Operation > < Mechanical Specifications
Page 1
background image

Refrigerant Pressure Sensor / Switch: Pressure, Vacuum and Temperature Specifications

A/C Cycling Switch

Close ........................................................................................................................................................................................ 324 kPa (47 psi) Maximum
Open ......................................................................................................................................................................................... 152 kPa (22 psi) Minimum