ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 5722 > < Initial Inspection and Diagnostic Overview
Page 1
background image

Torque Converter: Component Tests and General Diagnostics

Diagnosis

Prior to torque converter replacement, all diagnostic procedures must be followed. This is to prevent the unnecessary replacement of good torque
converters. Only after a complete diagnostic evaluation can the decision be made to replace the torque converter.

Begin with the normal diagnostic procedures as follows:
1. Preliminary Inspection.
2. Know and Understand the Customer's Concern.
3. Verify the Condition-Perform the Torque Converter Operation Test.
4. Perform Diagnostic Procedures.

-

Run on-board diagnostics.
-

Repair all non-transmission related DTCs first.

-

Repair all transmission DTCs.

-

Rerun on-board diagnostic to verify repair.

-

Perform Line Pressure Test.

-

Perform Stall Speed Test.

-

Perform Diagnostic Routines.
-

Use the Diagnosis by Symptom index to locate the appropriate routine that best describes the symptom(s). The routine will list all possible
components that may cause or contribute to the symptom. Check each component listed; diagnose and repair as required before changing
the torque converter.

End Play Check

Special Tools

1. Insert End Play Checking Tool into the torque converter pump drive.

1

Position End Play Checking Tool.

2

Tighten the inner post until the tool is securely locked.

Initial Inspection and Diagnostic Overview|Page 5722 > < Initial Inspection and Diagnostic Overview