ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 5729 > < Initial Inspection and Diagnostic Overview|Page 5727
Page 8
background image

Torque Converter End Play

-

If the reading exceeds end play limits, replace the torque converter.

4. Remove the dial indicator and tool.

Leakage Checks

Special Tools

1. Clean the outside surface of the torque converter.

2. Install the Torque Converter Leak Check Tool and Gasket into the converter hub.

3. WARNING:  Always follow proper safety procedures while using the press. 

Install the torque converter with the installed leak check tool into the Arbor press.

Secure the press. Apply enough force from the press to sea] the tool into the torque converter.

Initial Inspection and Diagnostic Overview|Page 5729 > < Initial Inspection and Diagnostic Overview|Page 5727