X5 Continued

Normal Operation

The trailer battery charging is accomplished through the use of the trailer tow battery charge relay. The trailer tow battery charge relay is supplied
voltage and ground through the central junction box (CJB). When energized, the trailer tow battery charge relay routes voltage from the CJB to the
trailer tow connector through circuit 49 (OG).

Possible Causes

-

Fuse

-

Circuit 49 (OG) open

-

Trailer tow battery charge relay

-

CJB

-

Trailer

Test Y: The Trailer Electric Brakes Are Inoperative/Do Not Operate Correctly

PINPOINT TEST Y: THE TRAILER ELECTRIC BRAKES ARE INOPERATIVE/DO NOT OPERATE CORRECTLY