ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Compressor Manifold and Tube Assembly|Page 2248 > < Compressor Manifold and Tube Assembly|Page 2246
Page 1
background image

Hose/Line HVAC: Service and Repair
Condenser to Evaporator Line

CONDENSER TO EVAPORATOR LINE

Removal and Installation

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.
2. Remove the powertrain control module (PCM).
3. Remove the PCM bracket.

1

Remove the 3 PCM bracket bolts.

2

Remove the PCM bracket.
-

To install, tighten to 10 Nm (89 lb-in).

4. Disconnect the evaporator inlet fitting.

-

Discard the O-ring seals.

5. Disconnect the condenser outlet fitting.

-

Discard the O-ring seal.

-

To install, tighten to 25 Nm (18 lb-ft).

6. Remove the condenser to evaporator line.

Compressor Manifold and Tube Assembly|Page 2248 > < Compressor Manifold and Tube Assembly|Page 2246