ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Temperature Blend Door Actuator|Page 7264 > < Temperature Blend Door Actuator
Page 2
background image

5. Remove the LH instrument panel lower nut and position the brace aside.

6. Disconnect the restraints control module (RCM) electrical connector.

7. Remove the RCM and bracket assembly.

1

Remove the bracket retaining bolts.

2

Remove the RCM and bracket assembly.

All vehicles

8. Remove the floor duct.

1

Remove the two screws (one each side).

2

Remove the floor duct.

Temperature Blend Door Actuator|Page 7264 > < Temperature Blend Door Actuator