ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Power Steering Line/Hose > < Hose/Line HVAC|Service Precautions|Page 2714
Page 2
background image

6. Remove the suction accumulator bracket clamp bolt.

7. Remove the condenser to evaporator line.

INSTALLATION

1. To install, reverse the removal procedure.

-

Install new O-ring seals lubricated in clean mineral oil.

-

Lubricate the refrigerant system with the correct amount of clean mineral oil.

9. Evacuate, leak test and charge the refrigerant system. Refer to:  Heating and Air Conditioning, Service and Repair, Evacuating and Charging,

See: Heating and Air Conditioning/Service and Repair/Evacuation and Charging

Power Steering Line/Hose > < Hose/Line HVAC|Service Precautions|Page 2714