6. NOTE:  Use a backup wrench to hold the line during disconnection to prevent damage to the line.

Disconnect the A/C manifold and tube assembly at the A/C condenser core.
-

Discard the O-ring seal.

7. Remove the nut.

8. Remove the A/C pressure cutoff switch.

-

Discard the O-ring seal.

9. Remove the A/C manifold and tube assembly.

INSTALLATION

1. To install, reverse the removal procedure.

-

Install new O-ring seals lubricated in clean mineral oil.

-

Lubricate the refrigerant system with the correct amount of clean mineral oil.

2. Evacuate, leak test and charge the refrigerant system.