Special Tool(s)

SPECIAL TOOL(S)

Fluorescent Dye Detection

NOTE:  Ford Motor Company vehicles are produced with R-134a fluorescent dye installed in the refrigerant system from the factory. The location of
leaks can be pinpointed by the bright yellow-green glow of the fluorescent dye under a UV lamp. Since more than one leak can exist, make sure to
inspect each component, line, and fitting in the refrigerant system for a leak.

1. Check for leaks using the special tool.

^

Inspect all components, lines, and fittings of the refrigerant system.

2. Recover the refrigerant.
3. Repair the refrigerant system leak(s).
4. Evacuate and charge the refrigerant system.
5. After the leak(s) is/are repaired, remove any traces of fluorescent dye with a general purpose oil solvent.