ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Refueling Vapor Recovery System > < Liquid Vapor Separator, Evaporative System|Service Precautions
Page 1
background image

Liquid Vapor Separator: Service and Repair

REMOVAL

1. Remove the fuel tank.

2. Remove the fuel vapor vent valve.

1

Slide the clamp away from the evaporative emission valve and remove the evaporative emission return tube.

2

Press down and rotate the evaporative emission valve counterclockwise and remove it from the fuel tank.

CAUTION:  The fuel vapor vent valve must be disengaged from the fuel tank before it can be removed. Rotate the fuel vapor vent valve
counterclockwise to disengage from the fuel tank. Failure to do so can cause damage to the fuel vapor vent valve or the fuel tank.

INSTALLATION

1. To install, reverse the removal procedure.

^

Leak test the system.  See: Testing and Inspection/Component Tests and General Diagnostics/Component Tests/Evaporative Emission System
Leak Test

^

Carry out the evaporative emission repair verification drive cycle.  See: Testing and Inspection/Component Tests and General
Diagnostics/Component Tests/Evaporative Emission Repair Verification Drive Cycle

Refueling Vapor Recovery System > < Liquid Vapor Separator, Evaporative System|Service Precautions