1. NOTE:  Prior to installing the manual control lever seal, clean the bore opening with mineral spirits.

Using the special tool, install the manual control lever seal.

2. Install the manual control lever shaft assembly.

1

Install the manual control lever shaft assembly.

2

Install and seat the manual lever shaft retaining pin below the case surface.

3

NOTE:  The inner manual valve detent lever must be seated on the flats of the manual control lever shaft assembly, and the parking pawl
actuating rod must be through the guide plate.

NOTE:  The manual control valve detent lever spring must be on the inner manual valve detent lever, and the detent lever pin must align with
the manual shift valve.

Install the parking pawl actuating rod and the inner manual valve detent lever.

4

NOTE:  Use a crescent wrench on the manual control lever or the outer flats of the manual control lever shaft assembly when installing the
inner manual valve detent lever nut.

Install the inner manual valve detent lever nut.

3. CAUTION:  Do not reuse the old filter and seal assembly.

CAUTION:  Make sure that the pump bore is clean and the old filter seal has been removed.

NOTE:  Prior to installation, lightly lubricate the fluid filter seal with clean automatic transmission fluid.

Install a new filter and seal assembly by pressing it into place.