F 250 2WD LD Pickup V8-4.6L SOHC VIN 6 (1997)
Compressor Fitting HVAC: Service and Repair
REMOVAL
CAUTION: Whenever a refrigerant line is replaced, it is necessary to replace the suction accumulator/drier.
1. Disconnect the battery ground cable.
2. Recover the refrigerant from the system. See: Service and Repair/Refrigerant Recovery
3. Remove the A/C air inlet duct.
4. Remove the manifold and tube assembly.
1. Remove the manifold to compressor bolt.
2. Remove the manifold and tube assembly.
5. Disconnect the A/C pressure cut-off switch electrical connector.
6. Disconnect the manifold and tube fitting at the accumulator drier.