ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Compressor Fitting HVAC|Specifications|Page 9200 > < Compressor Fitting HVAC|Specifications
Page 1
background image

Compressor Fitting HVAC: Service and Repair

REMOVAL

CAUTION:  Whenever a refrigerant line is replaced, it is necessary to replace the suction accumulator/drier.

1. Disconnect the battery ground cable.
2. Recover the refrigerant from the system. See: Service and Repair/Refrigerant Recovery
3. Remove the A/C air inlet duct.

4. Remove the manifold and tube assembly.

1. Remove the manifold to compressor bolt.
2. Remove the manifold and tube assembly.

5. Disconnect the A/C pressure cut-off switch electrical connector.

6. Disconnect the manifold and tube fitting at the accumulator drier.

Compressor Fitting HVAC|Specifications|Page 9200 > < Compressor Fitting HVAC|Specifications