2. Install Torque Converter Leak Check Tool and Gasket 01 4-R1075 into convert hub.

3. Position torque converter with installed leak check tool into the press.
4. Secure the press. Apply enough force from the press to seal tool into the torque converter.

WARNING:  ALWAYS FOLLOW PROPER SAFETY PROCEDURES WHILE USING PRESS. 

5. Apply air pressure to valve on leak check tool.

NOTE:  Use clean dry shop air.

6. With air pressure applied to valve, inspect for leaks at studs, seams and pilot hub. A soap bubble solution may be applied around those areas to aid

in diagnosis. If leaks are present, replace the converter.