ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Air Manifold Rails <--> [Air Injection Manifold] > < Air Injection Filter|Service and Repair
Page 1
background image

Air Injection Hose/Tube: Testing and Inspection

CAUTION: 

The hoses used with this system are made of special material to withstand high temperature. No other type should be used.

Procedure:

1. Inspect all hoses and tubes for deterioration or cracks.

2. Check hose and tube routing as interference may cause wear.

3. Check all hose and tube connections.

4. Check the pressure side of the system for leaks with a soapy water solution. With the pump running, bubbles will form if a leak exists.

5. When replacing any hose or tube, note routing before removal.

Air Manifold Rails <--> [Air Injection Manifold] > < Air Injection Filter|Service and Repair