background image

-

Place the fast idle adjustment mechanism on top step of fast idle cam. Check/adjust fast idle rpm to specification. See: Specifications

-

Recheck for repeatability.

-

Remove the plug from the EGR vacuum hose and reconnect.

Type 7200-VV Carburetor

FAST IDLE SPEED ADJUSTMENT

-

Place the transmission in Neutral (manual) or Park (automatic).

-

Bring the engine to normal operating temperature.

-

Disconnect purge hose on canister side of evaporator purge solenoid. Check to ensure that purge vacuum is present (solenoid has opened, will
require a 3-5 minute wait after starting engine, followed by a short time at part throttle. Reconnect purge hose.

-

Disconnect the vacuum hose at the EGR valve and plug.

-

Place the fast idle adjustment mechanism on the second step of the fast idle cam.

-

Check/adjust fast idle rpm to specification. Recheck for repeatability. See: Specifications

-

Remove the plug from the EGR vacuum hose and reconnect.