F 250 2WD Pickup V8-7.3L DSL Turbo VIN F (1994)
Vacuum Pump Switch: Service and Repair
Vacuum Hose Routing
Low Vacuum Switch
NOTE: The distributor modulator valve switch is mounted to the left side fender panel.
REMOVAL
1. Disconnect vacuum hose from distributor modulator valve switch.
2. Remove two attaching screws and remove distributor modulator valve switch and A/C compressor mounting bracket (2882).
INSTALLATION
1. Position distributor modulator valve switch and A/C compressor mounting bracket to panel and secure with two screws. Tighten screws to 8-11
Nm (6-8 ft lb).
2. Connect vacuum hose to distributor modulator valve switch.