1. Follow the removal procedure in reverse order.

-

Service the replacement A/C condenser with the correct amount of Motorcraft YN-12c refrigerant oil or equivalent meeting Ford specification
WSH-M1C231-B.

-

Lubricate the O-ring seals with Motorcraft YN-12c refrigerant oil F2AZ-19577-AB or equivalent meeting Ford specification
WSH-M1C231-B.