REMOVAL
1. Remove the generator.
2. Remove the generator brush and terminal holder and the voltage regulator.
1. Remove the four voltage regulator screws.
2. Remove the generator brush and terminal holder and the voltage regulator.
3. Separate the generator brush and terminal holder from the voltage regulator.
1. Remove the screw cap.
2. Remove the two generator brush and terminal holder screws.
3. Separate the generator brush and terminal holder from the voltage regulator.
INSTALLATION
1. Install the brush and terminal holder on the voltage regulator.
1. Position the brush and terminal holder on the voltage regulator.
2. Install the two generator brush and terminal holder screws.
3. Install the screw cap.
CAUTION: Make sure screw cap is installed over Test Terminal A to prevent accidental shorting of the battery positive connection.