ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Control Assembly, HVAC > < Condenser HVAC|Description and Operation|Page 8586
Page 2
background image

contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.
2. Remove the condenser inlet and outlet fitting nuts and disconnect the fittings.

-

Discard the O-ring seals and gasket seals.

-

To install, tighten to 15 Nm (11 lb-ft).

3. Detach the hood release cable pin-type retainer from the power steering cooler.
4. Remove the 2 power steering cooler bolts.

-

To install, tighten to 11 Nm (8 lb-ft).

5. Position the power steering cooler aside.
6. Remove the horn assembly bracket bolt and position the horn assembly aside.

-

To install, tighten to 11 Nm (8 lb-ft).

7. Remove the 2 condenser bolts.

-

To install, tighten to 11 Nm (8 lb-ft).

8. Remove the condenser core.
9. To install, reverse the removal procedure.

-

Install new gasket seals and O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

10. Evacuate, leak test and charge the refrigerant system.

Control Assembly, HVAC > < Condenser HVAC|Description and Operation|Page 8586