ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 10676 > < Initial Inspection and Diagnostic Overview|Page 10674
Page 4
background image

B1-B2

Normal Operation

The instrument cluster provides a ground circuit for the battery saver relay and the interior lamps relay. When the relays are energized, voltage is
supplied to the interior lamps on circuit 53 (BK/LB). The interior lamps are grounded through circuit 57 (BK).

Possible Causes

-

Circuit 53 (BK/LB) open

-

Circuit 57 (BK) open

-

Interior lamp assembly

Test C: The Interior Lamps Stay On Continuously

PINPOINT TEST C: THE INTERIOR LAMPS STAY ON CONTINUOUSLY

Initial Inspection and Diagnostic Overview|Page 10676 > < Initial Inspection and Diagnostic Overview|Page 10674