ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Heater Control Valve > < Expansion Valve|Service Precautions|Page 9808
Page 1
background image

Expansion Valve: Service and Repair

THERMOSTATIC EXPANSION VALVE

REMOVAL

CAUTION:  Refrigerant compressor oil F73Z-19577-AA (Motorcraft YN-9-A) should be used to lubricate R-134a refrigerant system O-ring
seals only and should not be added to R-134a refrigerant systems as an A/C compressor lubricant. PAG refrigerant compressor oil
F7AZ-19D589-DA (Motorcraft YN-12-C) or equivalent meeting Ford specification WSH-M1C231-B only should be used as an A/C compressor
lubricant.

1. Recover the refrigerant.
2. Remove the access panel from the RH rear quarter trim panel.
3. Remove the jack.

4. Remove the A/C lines from the thermostatic expansion valve (TXV).

1

Disconnect the A/C lines from the TXV.

2

Disconnect the TXV from the evaporator core.

INSTALLATION

1. To install, reverse the removal procedure.

-

Install new O-ring seals lubricated in clean mineral oil.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

2. Evacuate, leak test and charge the refrigerant system.

Heater Control Valve > < Expansion Valve|Service Precautions|Page 9808