ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

TorqShift|Page 7312 > < TorqShift|Page 7310
Page 1
background image

Valve Body: Service and Repair
4R100

Main Control Valve Body Accumulator Body, Solenoid Body 

Removal 

NOTE:  If the transmission has been disassembled to install new parts, and the valves in the main control valve body stick repeatedly from foreign
material, the torque converter must be removed and cleaned by using a suitable torque converter/fluid cooler cleaner.

1. With the vehicle in NEUTRAL, position it on a hoist. For additional information, refer Maintenance/Service and Repair.

2. Disconnect the solenoid body electrical connector.

3. NOTE:  Do not discard the fluid pan gasket unless damaged. This is a reusable gasket.

Remove the transmission fluid pan and gasket.
1

Loosen, but do not remove the bolts.

2

Remove the front and side bolts.

3

Lower the front of the fluid pan and allow the fluid to drain.

4

Remove the remaining fluid pan bolts and the fluid pan.

4. CAUTION:  If the seal remains in the pump bore, remove it carefully with a small screwdriver so as not to scratch or damage the aluminum bore.

NOTE:  After removal, discard the filter and seal assembly.

Remove the filter and seal assembly by carefully pulling and rotating the filter as necessary.

TorqShift|Page 7312 > < TorqShift|Page 7310