2. Attach the Dial Indicator with Bracketry to the End Play Checking Tool.

^

Position the (A) indicator button between the ridges on the converter housing and zero the (B) dial.

3. Lift up on the End Play Checking Tool as far as it will move and note the dial indicator reading.

^

If the reading exceeds end play limits, replace the Converter Assy.

4. Remove the dial indicator and tool.

Leakage Checks

Special Tools

1. Clean the outside surface of the Converter Assy.