Vacuum Control Motors: Customer Interest
A/C - No Airflow From Floor Vents

Article No. 
97-19-19

09/15/97

^

AIR CONDITIONING - NO AIRFLOW FROM FLOOR 
HEATER - NO AIRFLOW FROM FLOOR

LIGHT TRUCK: 
1997 EXPEDITION, F-150-350 SERIES

ISSUE: 
Airflow from the air conditioner or heater will not switch to FLOOR mode on some vehicles. This may be due to the panel/floor door vacuum motor
linkage being disconnected from the door pivot.

ACTION: 
Replace the vacuum motor assembly. Refer to the following Service Procedure for details.

SERVICE PROCEDURE

1.

Verify concern.

2.

Remove and replace panel/floor door Vacuum Motor (F75Z-18A318-AA). Refer to the appropriate Service Manual for removal procedure. Make
sure linkage is fully engaged in door pivot.

3.

Verify proper heating system operation.

PART NUMBER

PART NAME

F75Z-18A318-AA

Vacuum Motor Assembly

OTHER APPLICABLE ARTICLES: NONE

WARRANTY STATUS: Eligible Under The Provisions Of Bumper To Bumper Warranty Coverage

OPERATION

DESCRIPTION

TIME

971919A

Replace Vacuum Motor

0.6 Hr.

Assembly

DEALER CODING

CONDITION

BASIC PART NO.

CODE    

18A318

X2

OASIS CODES: 208000, 208300, 208999