F 250 4WD LD Pickup V8-5.4L SOHC VIN L (1997)
Alternator Brush: Service and Repair
REMOVAL
1. Remove the generator.
2. Remove the (A) generator brush and terminal holder and the (B) voltage regulator assembly.
1
Remove the voltage regulator screws.
2
Remove the (A) generator brush and terminal holder and (B) voltage regulator assembly.
3. Separate the (A) generator brush and terminal holder from the (B) voltage regulator.
1
Remove the screw cap.
2
Remove the generator brush and terminal holder screws.
3
Separate the (A) generator brush and terminal holder from the (B) voltage regulator.
INSTALLATION
1. Install the (A) brush and terminal holder on the (B) voltage regulator.
1
Position (A) brush and terminal holder on the (B) voltage regulator.
2
Install the generator brush and terminal holder screws.
3
Install the screw cap.
CAUTION: Make sure screw cap is installed over the proper screw to prevent accidental shorting of the battery positive connection.