ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Clockspring Assembly / Spiral Cable, Air Bag > < Recall - Airbag Diagnostic Monitor Replacement|Page 8638
Page 1
background image

Air Bag Control Module: Service and Repair

WARNING: THE ELECTRICAL CIRCUIT NECESSARY FOR SYSTEM DEPLOYMENT IS POWERED DIRECTLY FROM THE
BATTERY AND BACKUP POWER SUPPLY. TO AVOID ACCIDENTAL DEPLOYMENT AND POSSIBLE PERSONAL INJURY, THE
POSITIVE BATTERY CABLE MUST BE DISCONNECTED FOR ONE MINUTE PRIOR TO SERVICING OR REPLACING ANY
SYSTEM COMPONENTS.
 

REMOVAL

1. Disconnect positive battery cable and wait one minute for backup power supply energy to be depleted.

2. Locate air bag diagnostic monitor beneath and to the left of the steering column and disconnect the two connectors.
3. Depress tabs retaining air bag diagnostic monitor to air bag monitor bracket. Slide air bag diagnostic monitor off air bag monitor bracket.
4. Disconnect electrical wiring connectors to air bag diagnostic monitor. Remove air bag diagnostic monitor.

INSTALLATION 

1. For installation, follow removal procedures in reverse order.
2. Run system prove-out check.

NOTE:  When the battery is disconnected and reconnected, some abnormal drive symptoms may occur while the powertrain control module
relearns its adaptive strategy. The vehicle may need to be driven 10 miles or more to relearn the strategy.

Clockspring Assembly / Spiral Cable, Air Bag > < Recall - Airbag Diagnostic Monitor Replacement|Page 8638