ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Refrigerant Discharging and Recovery Procedure|Page 8086 > < Refrigerant Discharging and Recovery Procedure|Page 8084
Page 2
background image

120 Watt 110 Volt UV Lamp 20 Degree Celsius

SPECIAL TOOL(S)

NOTE:  Ford Motor Company vehicles are produced with a permanent leak tracer dye incorporated into the A/C system. The location of leaks can be
pinpointed by the bright yellow-green glow of the tracer dye. Since more than one leak can exist, always inspect each component.

1. Check for leaks using a 120 Watt UV spot lamp.

^

Scan all components, fittings and lines of the A/C system.

2. After the leak is repaired, remove any traces of tracer dye with a general purpose oil solvent.

3. Verify the repair by operating the system for a short time and inspect with the UV spot lamp.