Refrigerant: Service and Repair
Leak Detection

Electronic Leak Detection

Refrigerent Leak Detector

SPECIAL TOOL(S)

CAUTION:  Good ventilation is necessary in the area where electronic A/C leak testing is to be carried out. If the surrounding air is contaminated with 
refrigerant gas, the leak detector will indicate this gas all the time. Odors from other chemicals such as anti-freeze, diesel fuel, disc brake cleaner, or
other cleaning solvents can cause the same problem. A fan, even in a well-ventilated area, is very helpful in removing small traces of contamination from
the air that might affect the leak detector.

1. Leak test the refrigerant system using the Refrigerant Leak Detector. Follow the instructions included with the leak detector for handling and

operation techniques.

NOTE:  The system pressure should be between 413-551 kPa (60-80 psi) at 24°C (75°F) with the engine off.

2. If a leak is found, perform the Refrigerant Discharging and Recovery Procedure.

^

Repair the system.

^

Test the system for normal operation.

Tracer Dye Leak Detection

Refrigerant Discharging and Recovery Procedure|Page 7766 > < Refrigerant Discharging and Recovery Procedure|Page 7764