Ford Workshop Service and Repair Manuals

Bi-Fuel Models|Page 4070 > < Bi-Fuel Models
Page 2
background image

2. Close the liquid propane gas (LPG) tank manual tank valve on the aft-axle LPG tank if equipped.

3. Disconnect the liquid propane gas (LPG) tank relay(s).

NOTE:  Only one relay for single LPG tank system, two relays for dual tank LPG system.

4. Set the fuel selector switch to run on LPG and run the vehicle until the lamp goes out.

NOTE:  Residual pressure may still be present.

5. Repeat the previous step to make sure all LPG is removed from the lines.

NOTE:  If the vehicle is equipped with dual LPG tanks, repeat this step with the LPG switch selected for the other LPG tank.

6. To pressurize the fuel system, reinstall the tank relay(s), open manual tank valve(s), set the fuel selector switch to run on LPG and cycle the