ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Mechanical Specifications|Page 6905 > < Mechanical Specifications
Page 1
background image

Power Steering Pump: Pressure, Vacuum and Temperature Specifications

 

CII

Flow Rate @ 74 degrees - 80 degrees C (165 degrees - 175 degrees F) and Engine Speed Set at Idle

2.1 - 2.5 gal/min 

   

  

  

 

Pressure @ 74 degrees - 80 degrees C (165 degrees - 175 degrees F) and Engine Speed Set at Idle

150 psi 

    

 

  

  

 

Minimum Flow Rate @ 74 degrees - 80 degrees C (165 degrees - 175 degrees F) and Power Steering Analyzer Set at 5102

1.5 gal/min 

kPa (750 psi) 

    

 

  

  

 

Relief Pressure

1450 - 1530 psi 

    

 

  

  

 

CIII Flow Rate @ 74 degrees - 80 degrees C (165 degrees - 175 degrees F) and Engine Speed Set at Idle

2.8 - 3.2 gal/min 

   

  

  

 

Pressure @ 74 degrees - 80 degrees C (165 degrees - 175 degrees F) and Engine Speed Set at Idle

150 psi 

    

  

 

  

  

 

Minimum Flow Rate @ 74 degrees - 80 degrees C (165 degrees - 175 degrees F) and Power Steering Analyzer Set at 5102

1.4 gal/min 

kPa (750 psi) 

    

  

 

  

  

 

Relief Pressure

1400 - 1530 psi 

    

  

 

  

  

 

Mechanical Specifications|Page 6905 > < Mechanical Specifications