background image

5. Open the high-pressure service valve.

6. Open the special tool valves and inject the fluorescent dye into the refrigerant system.

7. Close the high-pressure service valve to allow the pressure inside the special tool to equalize with the suction side of the refrigerant system.

8. Close the valves on the special tool.

NOTE:  Close the valves on the special tool while the A/C compressor is operating.

9. Disconnect the high-pressure and low-pressure service valves and remove the special tool from the vehicle.

NOTE:  Leave all valves on the special tool closed when not in use.