Disconnect: Suspect Ajar Switch .

-

Do the courtesy lamps illuminate?

Yes

INSTALL a new ajar switch in question. TEST the system for normal operation.

No

GO to D2.

-------------------------------------------------
D2 CHECK THE AJAR SWITCH CIRCUIT FOR A SHORT TO GROUND

-

Disconnect: SJB C2280c.

-

Measure the resistance between the suspect ajar switch, harness side and ground as follows:

-

Is the resistance greater than 10,000 ohms?

Yes

GO to D3.

No

REPAIR the circuit in question. TEST the system for normal operation.

-------------------------------------------------
D3 CHECK FOR CORRECT SJB OPERATION

-

Disconnect all the SJB connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the SJB connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new SJB. TEST the system for normal operation.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.

-------------------------------------------------