ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Positive Crankcase Ventilation Valve > < Pressure Feedback Exhaust Sensor, EGR|Description and Operation
Page 1
background image

PCV Heater: Service and Repair

Positive Crankcase Ventilation (PCV) Heater Element - 5.4L

Removal

1. Disconnect the PCV heater element electrical connector.

2. Disconnect the quick connect couplings and remove the PCV tube.

3. Remove the 2 bolts and the PCV heater element.

-

Discard the PCV heater element.

Installation

1. Install the new PCV heater element and the 2 bolts.

-

Tighten to 10 Nm (89 lb-in).

2. Position the PCV tube and connect the quick connect couplings.

3. Connect the PCV heater element electrical connector.

Positive Crankcase Ventilation Valve > < Pressure Feedback Exhaust Sensor, EGR|Description and Operation