Extension Housing Gasket|Page 4748 > < Extension Housing Gasket|Page 4746
Page 3
background image

3. Connect the OSS sensor.

4. Using the Output Shaft Locknut Socket, install a new output shaft retaining nut.

-

Tighten to 200 Nm (148 lb-ft).

5. Install the transfer case.

6. Start the engine. Move the selector lever through all the gear ranges, checking for engagements.

7. With the vehicle in NEUTRAL, engine running and the transmission at normal operating temperature 66-77°C (150-170°F), check and adjust the

transmission fluid level, and check for any leaks. If transmission fluid is needed, add transmission fluid in increments of 0.24L (0.5 pt) until the
correct level is achieved (fluid should be in the hot range cross-hatched area of the transmission fluid level indicator).