ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Diagnosis|Page 5192 > < Diagnosis|Page 5190
Page 1
background image

Torque Converter: Testing and Inspection
Leakage Checks

Special Tools

1. Clean the outside surface of the Converter Assy.

2. Install the Torque Converter Leak Check Tool and Gasket into the converter hub.

3. WARNING:  ALWAYS FOLLOW PROPER SAFETY PROCEDURES WHILE USING THE PRESS. 

Install the Converter Assy. with the installed leak check tool into the Arbor press.

Secure the press. Apply enough force from the press to seal the tool into the Converter Assy.

4. NOTE:  Use clean, dry shop air.

Apply air pressure to the valve on the leak check tool.

Diagnosis|Page 5192 > < Diagnosis|Page 5190