Starter Motor: Testing and Inspection
Voltage Drop Tests

Starter Motor - Motor Feed Circuit Voltage Drop Test

1. This test is performed to determine if slow cranking is caused by high resistance in the starter motor circuit wiring.
2. The voltage drop test can only be performed with the starter motor on the vehicle.
3. Disconnect the wiring from the fuel shutoff solenoid.
4. Connect the positive lead of the 73 Digital Multimeter to the battery positive (+) post, and the negative lead to the starter solenoid M-terminal.
5. Connect a remote starter switch between the starter solenoid S-terminal and the positive battery terminal post.
6. Press the remote starter switch and record the voltage reading.
7. The voltage reading should be 0.5 volt or less. A reading higher than 0.5 volt indicates high resistance.
8. Repeat the test on the starter solenoid B-terminal.
9. If the readings are higher than 0.5 volt, remove the wiring from the starter solenoid.

10. Clean and inspect each wire connector and the starter solenoid terminals.
11. Install the wires onto the starter solenoid and retest.
12. If the reading at the starter solenoid M-terminal is still higher than 0.5 volt or the reading at the B-terminal is lower, carry out the Starter Solenoid

Component Test. If no change is noted, install a new positive battery cable lead.  See: Testing and Inspection/Component Tests and General
Diagnostics/Starter Solenoid

Starter Motor - Motor Ground Circuit Voltage Drop Test

NOTE:  A slow cranking condition can also be caused by high resistance in the ground circuit.

1. Disconnect the wiring from the fuel shutoff solenoid.
2. Connect the Digital Volt-Ohmmeter positive lead to the starter motor housing.
3. Connect the Digital Volt-Ohmmeter negative lead to the battery negative (-) terminal.
4. Connect a remote starter switch between the starter solenoid S-terminal and the positive battery terminal post.
5. Press the remote starter switch and record the voltage reading.
6. The voltage reading should be 0.2 volt or less. If the voltage reading is higher, remove and clean the negative cable connections at the battery, 

starter motor and the body.

7. Retest the system. If readings are still higher than 0.2 volt, test each individual negative cable.