Place the fast idle adjustment mechanism on top step of fast idle cam. Check/adjust fast idle rpm to specification. See: Specifications

-

Recheck for repeatability.

-

Remove the plug from the EGR vacuum hose and reconnect.

Type 7200-VV Carburetor

FAST IDLE SPEED ADJUSTMENT

-

Place the transmission in Neutral (manual) or Park (automatic).

-

Bring the engine to normal operating temperature.

-

Disconnect purge hose on canister side of evaporator purge solenoid. Check to ensure that purge vacuum is present (solenoid has opened, will
require a 3-5 minute wait after starting engine, followed by a short time at part throttle. Reconnect purge hose.

-

Disconnect the vacuum hose at the EGR valve and plug.

-

Place the fast idle adjustment mechanism on the second step of the fast idle cam.

-

Check/adjust fast idle rpm to specification. Recheck for repeatability. See: Specifications

-

Remove the plug from the EGR vacuum hose and reconnect.

Heavy Duty, GVW Over 8500 Pounds

1983 351W Over 8500 Lbs. Gross Vehicle Weight

1.

Place manual transmission in neutral or automatic transmission in park.