15. Remove A/C compressor pressure relief valve from old A/C manifold and tube and install in new A/C manifold and tube.
16. Connect electrical connector to A/C pressure cut-off switch.
17. Tighten connection at suction accumulator/drier to A/C manifold and tube suction line to 41-47 Nm (30-35 lb-ft). Use a wrench on each side of

connection.

18. Tighten connection at A/C manifold and tube discharge line to A/C condenser core to 21-27 Nm (15-20 lb-ft). Use a wrench on each side of

connection.

19. Connect the battery ground cable.

NOTE:  When the battery has been disconnected and reconnected, some abnormal drive symptoms may occur while the Powertrain Control
Module (PCM) relearns its adaptive strategy. The vehicle may need to be driven 16 km (10 miles) or more to learn the strategy.

20. Recover, leak test, and charge the A/C system. Observe all safety precautions. See: Service and Repair
21. The addition of refrigerant oil is not necessary when installing a new refrigerant line unless the line has been replaced due to bursting while

containing a refrigerant charge.