F 350 2WD Super Duty V10-6.8L (2009)
-
Is any voltage present?
Yes
GO to AD11.
No
INSTALL a new trailer battery charge relay. TEST the system for normal operation.
-------------------------------------------------
AD11 CHECK THE TRAILER BATTERY CHARGE RELAY COIL SUPPLY CIRCUIT FOR A SHORT TO VOLTAGE
-
Disconnect: SJB C2280b.
-
Measure the voltage between the trailer battery charge relay pin 85, circuit CBP33 (WH/BN), BJB face side and ground.
-
Is any voltage present?
Yes
REPAIR circuit CBP33 (WH/BN) for a short to voltage. TEST the system for normal operation.
No
GO to AD12.
-------------------------------------------------
AD12 CHECK FOR CORRECT SJB OPERATION
-
Disconnect all the SJB connectors.
-
Check for:
-
corrosion