ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

A/C Compressor Pressure Relief Valve|Page 6265 > < A/C Compressor Pressure Relief Valve
Page 1
background image

High Pressure Safety Valve HVAC: Description and Operation
High-Pressure Cutoff Switch

Air Conditioning

High-Pressure Cutoff Switch - 5.4L and 6.8L

The high-pressure cutoff switch is used to interrupt A/C compressor operation in the event of excessively high discharge pressure in the high-pressure
side of the refrigerant system. The PCM monitors the contacts in the high-pressure cutoff switch. When the high-pressure cutoff switch is open, the PCM
will disengage the A/C compressor clutch.

The high-pressure cutoff switch is located on a Schrader-type valve fitting on the compressor-to-condenser discharge line. It is not necessary to recover
the refrigerant to remove the high-pressure cutoff switch.

A/C Compressor Pressure Relief Valve|Page 6265 > < A/C Compressor Pressure Relief Valve