ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Housing Assembly HVAC > < Compressor to Condenser Discharge Line|Page 6273
Page 2
background image

5. Remove the suction accumulator outlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 15 Nm (133 lb-in).

6. Remove the A/C compressor suction fitting nut and disconnect the fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 15 Nm (133 lb-in).

7. Remove the suction accumulator-to-compressor line.

8. To install, reverse the removal procedure.

-

Install new gasket seals and O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

9. Evacuate, leak test and charge the refrigerant system.

Housing Assembly HVAC > < Compressor to Condenser Discharge Line|Page 6273