ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 8609 > < Initial Inspection and Diagnostic Overview|Page 8607
Page 3
background image

-

Measure the voltage between the suspect interior lamp pins, harness side as follows:

-

Is the voltage greater than 10 volts?

Yes

INSTALL a new interior lamp for the lamp in question. REFER to Interior Lamp  See: Dome Lamp/Service and Repair. TEST the system for normal
operation.

No

GO to B2.

-------------------------------------------------
B2 CHECK CIRCUIT CLN03 (YE/GY) FOR VOLTAGE

-

Measure the voltage between the suspect interior lamp, harness side and ground as follows:

-

Is the voltage greater than 10 volts?

Yes

REPAIR circuit GD179 (BK/VT) for an open. TEST the system for normal operation.

No

REPAIR circuit CLN03 (YE/GY) for an open. TEST the system for normal operation.

-------------------------------------------------

Pinpoint Test C: The Courtesy Lamps Stay On Continuously

Interior Lighting

Pinpoint Tests

Pinpoint Test C: The Courtesy Lamps Stay On Continuously

Refer to Wiring Diagram Set 89, Interior Lamps for schematic and connector information.  See: Diagrams/Electrical Diagrams/Diagrams By Number

Refer to Wiring Diagram Set 117, Remote Keyless Entry and Alarm for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

Normal Operation

When any door is opened, the ajar switch opens the circuit to the Smart Junction Box (SJB). The SJB monitors the ajar circuits, and based on the ajar
status, the SJB supplies voltage to the courtesy lamps on circuits CLN03 (YE/GY) (interior), CLN26 (BU) (cargo) and CLN25 (VT) (running boards).

Initial Inspection and Diagnostic Overview|Page 8609 > < Initial Inspection and Diagnostic Overview|Page 8607