ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3102 > < Initial Inspection and Diagnostic Overview|Page 3100
Page 31
background image

-

Is the voltage greater than 10 volts?

Yes

GO to M2.

No

VERIFY the Smart Junction Box (SJB) fuse 40 (20A) is OK. If OK, REPAIR the circuit in question. If not OK, REFER to the Wiring Diagrams to
identify the possible causes of the circuit short. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
M2 CHECK THE SDARS MODULE GROUND CIRCUIT FOR AN OPEN

-

Ignition OFF.

-

Disconnect: Negative Battery Cable.

-

Measure the resistance between the SDARS module C2400-3, circuit GD114 (BK/BU), harness side and ground.

-

Is the resistance less than 5 ohms?

Yes

GO to M3.

No

REPAIR the circuit. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
M3 CHECK THE MS-CAN CIRCUITS BETWEEN THE SDARS MODULE AND THE
DLC FOR AN OPEN

-

Measure the resistance between the SDARS module C2400-1, circuit VDB06 (GY/OG), harness side and the Data Link Connector (DLC) C251-3,
circuit VDB06 (GY/OG), harness side.

-

Measure the resistance between the SDARS module C2400-7, circuit VDB07 (VT/OG), harness side and the DLC C251-11, circuit VDB07
(VT/OG), harness side.

Initial Inspection and Diagnostic Overview|Page 3102 > < Initial Inspection and Diagnostic Overview|Page 3100