F 350 2WD Super Duty V10-6.8L (2009)
Intake Air Duct: Service and Repair
Air Cleaner Outlet Pipe
Air Cleaner Outlet Pipe - Gasoline Engines
Removal and Installation
All engines
1. Disconnect the degas bottle coolant hose from the Air Cleaner (ACL) outlet pipe.
6.8L (3V) engine
2. Disconnect the crankcase ventilation tube quick connect coupling from the ACL outlet pipe.
All engines
3. Loosen the 2 clamps and remove the ACL outlet pipe.
-
To install, tighten to 4 Nm (35 lb-in).
4. To install, reverse the removal procedure.