ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Leak Detection Solenoid, Evaporative System > < Fuel System - Difficult Fuel Fill/Nozzle Shuts Off|Page 4090
Page 7
background image

6. Install the EVAP canister vent solenoid and dust separator assembly to the EVAP canister assembly.

All vehicles
7. Install the EVAP canister and bracket assembly into the vehicle and install the 4 bolts.

-

Tighten to 17 Nm (13 lb-ft).

Aft-of-axle and auxiliary fuel tank equipped vehicles
8. If disconnected, connect the FPDM electrical connector to the FPDM.
9. Connect the fuel vapor vent hose to the dust separator.

10. Connect the fuel tank vapor tube-to-EVAP canister assembly quick connect coupling.

All vehicles
11. Connect the EVAP canister vent solenoid electrical connector.

Midship fuel tank equipped vehicles
12. Connect the EVAP canister purge valve vapor tube-to-EVAP canister assembly quick connect coupling and fuel tank vapor tube-to-EVAP canister

assembly quick connect coupling.

13. Connect the battery ground.

All vehicles
14. Carry out the EVAP system leak test.  See: Testing and Inspection
15. Carry out the EVAP repair verification drive cycle.

Leak Detection Solenoid, Evaporative System > < Fuel System - Difficult Fuel Fill/Nozzle Shuts Off|Page 4090