ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Positive Crankcase Ventilation Valve > < Pressure Feedback Exhaust Sensor, EGR|Description and Operation|Page 4134
Page 1
background image

PCV Heater: Service and Repair

POSITIVE CRANKCASE VENTILATION (PCV) HEATER ELEMENT

Removal

1. Disconnect the PCV heater element electrical connector.
2. Disconnect the quick connect couplings and remove the PCV tube.
3. Remove the 2 bolts and the PCV heater element.

-

Discard the O-ring seal.

Installation

1. NOTE:  Lubricate the O-ring seal with clean engine oil prior to installation.

Using a new O-ring seal, install the PCV heater element and the bolt.
-

Tighten to 10 Nm (89 lb-in).

2. Position the PCV tube and connect the quick connect couplings.
3. Connect the PCV heater element electrical connector.

Positive Crankcase Ventilation Valve > < Pressure Feedback Exhaust Sensor, EGR|Description and Operation|Page 4134