ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Valve Cover - LH|Page 2947 > < Valve Cover - LH|Page 2945
Page 4
background image

1. NOTE:  If the valve cover is not secured within 4 minutes, the sealant must be removed and the sealing area cleaned with silicone gasket remover

and metal surface prep. Follow the directions on the packaging. Allow to dry until there is no sign of wetness, or 4 minutes, whichever is longer.
Failure to follow this procedure can cause future oil leakage.

Apply a bead of silicone gasket and sealant in 2 places where the engine front cover meets the cylinder head.

2. Position the LH valve cover and a new gasket on the cylinder head and tighten the bolts in the sequence shown.

^

Tighten to 10 Nm (89 inch lbs.).

3. Position the intake manifold vacuum tube assembly onto the support bracket and the valve cover stud.
4. Connect the VCT solenoid electrical connector and the wiring harness retainers.
5. Connect the radio ignition interference capacitor electrical connector.
6. Position the PCV tube and connect the quick connect couplings. For additional information, refer to Fuel Delivery and Air Induction.
7. Connect the intake manifold vacuum tube hose to the brake booster.
8. Install the oil level indicator and tube. For additional information, refer to Oil Level Indicator and Tube.
9. Install the LH ignition coils. For additional information, refer to Ignition System.

10. Install the air cleaner intake pipe. For additional information, refer to Fuel Delivery and Air Induction.

Valve Cover - LH|Page 2947 > < Valve Cover - LH|Page 2945