ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Water Pump > < Cooling System - Repeat Radiator Leaks|Page 2578
Page 3
background image

4. Connect the wiring to the heater return tube.

5. Position the lower vertical EGR cooler bracket and loosely install the bolt.

6. Install a new vertical EGR cooler lower clamp. Tighten the clamp nut in 3 stages.

-

Stage 1: Tighten the nut to 10 Nm (89 lb-in).

-

Stage 2: Loosen the nut 720 degrees (2 complete turns).

-

Stage 3: Tighten the nut to 8 Nm (71 lb-in).

7. Tighten the lower EGR cooler bracket bolt.

-

Tighten to 62 Nm (46 lb-ft).

8. Connect the upper radiator hose to the thermostat housing. Install the spring clip.

-

Verify the spring clip is correctly seated.

9. Install the degas bottle. For additional information, refer to Degas Bottle - 6.4L Diesel  See: Coolant Reservoir/Service and Repair/Degas Bottle.

10. Install the upper cooling fan shroud. For additional information, refer to Cooling Fan Shroud - 6.4L Diesel, Upper  See: Fan Shroud/Service and

Repair/Cooling Fan Shroud - Upper.

Water Pump > < Cooling System - Repeat Radiator Leaks|Page 2578