9. NOTE: The EGR Valve Puller has a LH thread.

Install the EGR Valve Puller top plate and run the top plate down until it sits on the support rod nuts.

-

It may be necessary to adjust the support rods so that the plate sits squarely on top of the nuts.

10. NOTE: The EGR Valve Puller has a LH thread.

Using the EGR Valve Puller, remove the EGR valve.

-

Discard the O-ring seal.

11. Using the EGR Valve Cleaning Brush and a shop vacuum, clean the EGR valve bore in the intake throttle adapter.

-

Inspect the intake throttle adapter bore for scoring. If the bore is scored, install a new intake throttle adapter.

Installation

All vehicles

1. Using a new O-ring seal, install the EGR valve and the 3 bolts.

-

Tighten to 10 Nm (89 lb-in).

Early build vehicles

2. Connect the coolant inlet and outlet hoses.

All vehicles

3. Connect the EGRT sensor outlet and the EGR valve electrical connectors.

4. NOTE: Clearing the DTCs or Keep Alive Memory (KAM) does not reset the adaptive values in the PCM.